241 Fremont Ave N has 22 municipal building permits on file in Harrison. The latest recorded activity was a commercial permit dated May 13, 2026. Permits at this address represent $1MM–$5MM in total declared construction value. PropertyLabs also identified 40 mapped permits within 2 km of this address.
New pergola -ACW certificate of occupancy required: no special inspections required: no 2020 MSBC architect: Dean, Christian Daniel engineer: Milkert, Craig Allan
New retaining walls, ramps and fencing. Work in addition to BLDG1138212 SAC: _52.17_CHARGES _43.36_CREDITS = _8.81 or 9_NET MET COUNCIL LETTER DATED _8/20/25_ Engineer: ERA Michael…
Source Information is Not Available. Source Data Does Not Meet Reporting Standards. Please Review and Correct Source.
HVAC system, installing kitchen equipment per approved plans.
Scope includes bar and kitchen fixtures for a remodeling project. All plumbing shall be installed in accordance with the 2020 Minnesota State Plumbing Code (MSPC), Chapter 4714. Al…
40 mapped permits within 2 km, shown on the intelligence map above.
12 other addresses on Fremont Ave N with municipal permit records in Minneapolis.
This address has 22 permit records in PropertyLabs' public history and is located in Harrison. The city figures below provide context without changing the focus of this exact-address record.
City coverage counts address-linked rows and does not add overlapping canonical tables. Rolling windows are inclusive, use UTC boundaries, and end Jul 29, 2026.
PropertyLabs compiled this permit history from municipal public records for Minneapolis, MN. The latest recorded permit activity at 241 Fremont Ave N is dated May 13, 2026. Municipal records can be corrected or updated after publication.
See the contractors, applicants, permit holders, permit numbers, and project documents associated with 241 Fremont Ave N in the PropertyLabs platform, along with alerts when new permits are filed at this address.
certificate of occupancy required: NO mechanical plans required for certificate of occupancy mechanical plans/letter of means of compliance submitted\ special inspections required:…
New outdoor seating to the north Inspector note: temporary outdoor seating in east parking lot is no longer approved for occupancy certificate of occupancy required: no const type:…
Assembling a ventless kitchen hood that is listed UL 710B. The contactor been informed about the cooling load of the ventless kitchen hoods.
add roof hach and ships ladder for mechanical roof access. also providing guardrails at roof level. sck#2
HVAC-ROYAL FOUNDRY/ CRAFT BREWERY - 4 RTU'S (2) @ 310MBH/15 TON & (2) @ 224MBH/10 TON, 1 UNIT HEATER @ 150MBHDISTRIBUTION AND 800CFM EXHAUST PER ENGINEERED DRAWING
2 ROOF DRAINS
Install low pressure steam boiler, steam and condensate piping to brewing equipment, boiler exhaust flue and install 10-ton chiller and piping distribution to (4) fermentation tank
INSTALL 2 RTUS 1 @ 15 TON/350MBH &1 @ 5 TON/115MBH, TOILET EXHAUST AND DISTRUBUTION PER ENGINEERED DRAWING STRUCTURAL VERIFACATION REQUIRED ON SITE
ROYAL FOUNDRY CRAFT SPIRITS
LA DONA BREWERY - INSTALL WALK/IN COOLER @ 42,000BTUH
run drain, vent, and water for new brewery
EXISTING SPACE BEING RENOVATED INTO A BREWERY. COMPLETE REMODEL OF INTERIOR. ***************ARCHITECT (AARON WITTKAMPER) UPDATED STEPS OUTSIDE EXIT DOOR TO MATCH GRADE ON 7/24/18.…
New Bar/Distillery in Existing Warehouse Building certificate of occupancy required: yes mechanical plans required for certificate of occupancy mechanical plans/letter of means of…
chiller and boiler
SELECT DEMO OF PARTITION WALLS AND RESTROOMS OF OFFICES. (DMH#2) ADDITIONAL PLANS, PERMITS AND APPROVALS REQUIRED FOR REMODEL. APPROVED PLANS AND PERMIT MUST BE ON SITE BEFORE INSP…
RE-ROOF - REMOVE MEMBRANE INSTALL Z"S15 MECHANICALLY FASTENED SYSTEM & 60MIL TPO (MAA #02)
Plumbing · Jul 27, 2026